| Site Work & Foundations | Building Walls | Interior Finishes | Doors & Windows | Exterior Finishes | Plumbing & Electrical | Product Specifications | Design Details | Support Reports |
MANUFACTURERS SPECIFICATIONS
8.1 Manufacturers Technical Specifications
|
Property |
Test or Standard |
Product |
Value |
|
Part Size |
|
SF10 |
10" x 10" x 40" |
|
|
|
12VWF4 12VWF6 12VWF8 12VWF10 12VWF12 |
8" x 12" x 40" 10" x 12" x 40" 12" x 12" x 40" 14” x 12” x 40” 16” x 12” x 40” |
|
Average EPS Wall Thickness |
|
SF10 VWF |
1.75" 2.125" |
|
Concrete Wall Thickness |
|
SF10 |
6.5" |
|
|
|
12VWF4 |
3.75" |
|
|
|
12VWF6 |
5.75" |
|
|
|
12VWF8 |
7.75" |
|
|
|
12VWF10 |
9.75” |
|
Color |
|
EPS forms |
Light gray |
|
|
|
VWC4 |
Yellow |
|
|
|
VWC6 |
Blue |
|
|
|
VWC8 |
Red |
|
|
|
VWC10 |
Black |
|
VWC12 |
Gray |
||
|
Insulation Value |
ASTM C-236 Fully grouted |
SF10 |
0.057 UR-22 Equivalent* |
|
|
ASTM C-177 ASTM C-518 |
12VWF4 |
0.048 U R-24 Equivalent* |
|
|
ASTM C-177 ASTM C-518 |
12VWF6 |
0.047 U R-24 Equivalent* |
|
|
ASTM C-177 ASTM C-518 |
12VWF8 |
0.046 U R-24 Equivalent* |
|
|
ASTM C-177 ASTM C-518 |
12VWF10 |
0.045 U R-24 Equivalent* |
|
|
ASTM C-177 ASTM C-518 |
12VWF12 |
0.043 U R-24 Equivalent* |
|
STC Rating (inc. 2 layers 1/2" Gypsum drywall) |
|
SF10 VWF4 VWF6 VWF8 VWF10 VWF12 |
STC-52+ STC-44+ STC-55+ STC-58+ STC-59+ STC-60+ |
|
Flame Spread |
ASTM E-84 UBC Standard 42-1 |
|
10 (5##) |
|
Smoke Development |
ASTM E-84 UBC Standard 42-1 |
|
45-125 (75##) |
| Property | Test or Standard | Product | Value |
|
15 Minute Thermal Barrier |
UBC Standard 17-5, 1991 UBC Section 1713(d), 1991 |
|
Compliance (UC Berkeley) |
|
Exposure in a crawl space |
UBC Section 1713(d)D, 1991 |
|
Compliance (Southwest Research Institute) |
|
SmartBlock EPS Specifications |
|
Value at 1.5 PCF |
Value at 2.0 PCF |
|
Flexural Strength |
ASTM C-203 |
50psi |
75psi |
|
Compressive Strength |
ASTM D-1621 |
25psi |
33psi |
|
Density |
ASTM C-303 |
1.5 PCF |
2.0 PCF |
|
Shear Strength |
ASTM C-273 |
32psi |
37psi |
|
Tensile Strength |
ASTM D-1623 |
22psi |
27psi |
|
Water Vapor Transmission |
ASTM C-355 |
0.7-1.4 PERM/IN |
0.7-1.4 PERM/IN |
|
Water Absorption |
ASTM C-272 |
<2% by volume |
<2% by volume |
|
Capillarity |
None |
None |
|
|
Coefficient of thermal expansion |
ASTM D-696 |
0.000035 in/in/°F |
0.000035 in/in/°F |
|
Flash ignition temperature |
ASTM D-1929 |
675 °F |
675 °F |
|
Self ignition temperature |
ASTM D-1929 |
675 °F |
675 °F |
|
Maximum Temperature |
|
165 °F |
165 °F |
|
BTU Content |
ASTM D-2015 NFPA-259 |
17,000 BTU/ lb. |
17,000 BTU/ lb. |
*The R-value equivalent stated refers to a comparison of a SmartBlock insulating form wall versus wood framing 16" on center with the cavities filled with fiberglass batt insulation. This is the "standard" that is used when comparing R-values and thermal insulation factors for use with the various energy agencies.