SmartBlock™Design and Product Manual

October 2002 Edition

Introduction

Site Work & Foundations Building Walls Interior Finishes Doors & Windows Exterior Finishes Plumbing & Electrical Product Specifications Design Details Support Reports
Chapter 8

You can download and print this chapter in PDF Adobe Acrobat format   

MANUFACTURERS SPECIFICATIONS

8.1 Manufacturers Technical Specifications

Property

Test or Standard

Product

Value

Part Size

 

SF10

10" x 10" x 40"

 

 

12VWF4

12VWF6

12VWF8

12VWF10

12VWF12

8" x 12" x 40"

10" x 12" x 40"

12" x 12" x 40"

14” x 12” x 40”

16” x 12” x 40”

Average EPS Wall Thickness

 

SF10

VWF

1.75"

2.125"

Concrete Wall Thickness

 

SF10

6.5"

 

 

12VWF4

3.75"

 

 

12VWF6

5.75"

 

 

12VWF8

7.75"

 

 

12VWF10

9.75”

Color

 

EPS forms

Light gray

 

 

VWC4 

Yellow

 

 

VWC6

Blue

 

 

VWC8

Red

 

 

VWC10

Black

VWC12

Gray

Insulation Value

ASTM C-236

Fully grouted

SF10

0.057 UR-22 Equivalent*

 

ASTM C-177

ASTM C-518

12VWF4

0.048 U

R-24 Equivalent*

 

ASTM C-177

ASTM C-518

12VWF6

0.047 U

R-24 Equivalent*

 

ASTM C-177

ASTM C-518

12VWF8

0.046 U

R-24 Equivalent*

 

ASTM C-177

ASTM C-518

12VWF10

0.045 U

R-24 Equivalent*

 

ASTM C-177

ASTM C-518

12VWF12

0.043 U

R-24 Equivalent*

STC Rating

(inc. 2 layers 1/2" Gypsum drywall)

 

SF10

VWF4

VWF6

VWF8

VWF10

VWF12

STC-52+

STC-44+

STC-55+

STC-58+

STC-59+

STC-60+

Flame Spread

ASTM E-84

UBC Standard 42-1

 

10 (5##)

Smoke Development 

ASTM E-84

UBC Standard 42-1

 

45-125 (75##)

 

Property Test or Standard Product Value

15 Minute Thermal Barrier

UBC Standard 17-5, 1991

UBC Section 1713(d), 1991

 

Compliance

(UC Berkeley)

Exposure in a crawl space

UBC Section 1713(d)D, 1991

 

Compliance 

(Southwest Research Institute)

 

SmartBlock EPS Specifications

 

Value at 1.5 PCF

Value at 2.0 PCF

Flexural Strength

ASTM C-203

50psi

75psi

Compressive Strength

ASTM D-1621

25psi

33psi

Density

ASTM C-303

1.5 PCF

2.0 PCF

Shear Strength

ASTM C-273

32psi

37psi

Tensile Strength

ASTM D-1623

22psi

27psi

Water Vapor Transmission

ASTM C-355

0.7-1.4 PERM/IN

0.7-1.4 PERM/IN

Water Absorption

ASTM C-272

<2% by volume

<2% by volume

Capillarity

None

None

Coefficient of thermal expansion

ASTM D-696

0.000035 in/in/°F

0.000035 in/in/°F

Flash ignition temperature

ASTM D-1929

675 °F

675 °F

Self ignition temperature

ASTM D-1929

675 °F

675 °F

Maximum Temperature

 

165 °F

165 °F

BTU Content

ASTM D-2015

NFPA-259

17,000 BTU/ lb.

17,000 BTU/ lb.

*The R-value equivalent stated refers to a comparison of a SmartBlock insulating form wall versus wood framing 16" on center with the cavities filled with fiberglass batt insulation.  This is the "standard" that is used when comparing R-values and thermal insulation factors for use with the various energy agencies.

You will need PDF Adobe software to see the rest of this chapter.

8.2 Energy Analysis
8.2.1 SF10 Series
8.2.2 12VWF Series
8.3 Sound Transmission
8.4 Concrete Specifications
8.5 Concrete Estimation

 

Introduction

Site Work & Foundations Building Walls Interior Finishes Doors & Windows Exterior Finishes Plumbing & Electrical Product Specifications Design Details Support Reports

 
    Home Advantage   Feedback Pictures Q&A   Search Support Technical Info

 

©1989-2002 American ConForm